Ore pulp flow measurement at ball mill, SAG mill, and rod mill discharge
Grinding circuit slurry carries hard silica and ore particles at velocities that rapidly erode standard linings. Slurry-grade electromagnetic meters with polyurethane or hard rubber lining and tungsten carbide coated electrodes are the industry standard — the full-bore, zero-obstruction design generates no pressure drop that would affect mill circuit hydraulics, and the wear-resistant construction holds calibration through full grinding campaigns between liner changes.