Orifice Plate Flow Meter
The standard orifice is the simplest and most adaptable product among the throttling devices. Its design, manufacture and use are in compliance with the international standard IS05167 or the national standard GB/T2624.
-
Tel:
+86 13353783678 -
E-mail:
info@hbmeter.cc
Overview
The standard orifice is the simplest and most adaptable product among the throttling devices. Its design, manufacture and use are in compliance with the international standard IS05167 or the national standard GB/T2624.
Features
- 01It can measure the flow of various gases, liquids, and steams, and has a wide range of applications.
- 02The structure is simple, firm, easy to install, reliable in work, and stable in performance.
- 03No real-flow calibration is required, and the accuracy is moderate. It can be equipped with an intelligent differential pressure transmitter to realize temperature and pressure compensation or fieldbus communication letter way.
technical parameter
Pressure taking method | Corner connection (ring chamber or separate drilling), flange pressure, and diameter pressure. |
Nominal pressure (MPa) | ≤40 (after ≥20MPa, use high-pressure lens orifice or all-welded type.) |
Nominal diameter (mm) | DN50~1000 (standard orifice plate) or DN<50 (inner orifice plate), DN>1000 (flat orifice plate) |
Accuracy (uncertainty) | ±0.5%~±1.5% |