Sanitary Electromagnetic Flowmeter
The electromagnetic flowmeter is not easy to be polluted during use, and can be widely used in the production and manufacturing process of mineral water, soy sauce, jam, beer, juice, rice wine, milk and other foods, as well as in the fields of hygiene and chemical industry.
-
Tel:
+86 13353783678 -
E-mail:
info@hbmeter.cc
Product description
The HBLD/S sanitary electromagnetic flowmeter adopts new sanitary lining materials and lining technology, which meets the sanitary requirements of the food industry. At the same time, it adopts a stainless steel shell and a stainless steel clamp connection, which facilitates the rapid disassembly and cleaning of the flowmeter, and makes it a sanitary type. The electromagnetic flowmeter is not easy to be polluted during use, and can be widely used in the production and manufacturing process of mineral water, soy sauce, jam, beer, juice, rice wine, milk and other foods, as well as in the fields of hygiene and chemical industry.
Features
- 01The use of new sanitary lining materials prevents the accumulation of measuring medium residues in the measuring tube.
- 02Using the quick connection scheme, the electromagnetic flowmeter is easy to disassemble, maintain and clean.
- 03Using 16-bit embedded microprocessor for signal processing, it has the characteristics of high integration, fast calculation speed, high calculation accuracy, fully digital signal processing, strong anti-interference ability, and reliable measurement.
technical parameter
————————Technical parameter——————— | ||
Applicable medium | Food and wine industry | |
Caliber range | DN15-DN200 | |
Lining type | PTFE, F46, PFA; | |
Electrode type | 316L, Ha B, Ha C, titanium, tantalum, platinum-iridium alloy, stainless steel tungsten carbide | |
Pressure range | 0.6-4.0Mpa; | |
Temperature resistance | -25~80℃; | |
Accuracy | ±0.5% | |
Protection level | Sensor IP65\IP67\IP68 (optional), converter IP65 | |
Clamp electromagnetic Flow meter | Output type | Frequency, pulse, 4-20mA, RS485, Modbus protocol; Hart protocol (optional), Profibus DP (optional) |
Clamp Connection Sensor Size
Nominal diameter (DN) | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 |
L(mm)
PTFE/F46/PFA |
267 | 267 | 267 | 267 | 267 | 267 | 287 | 287 | 287 | 287 |
H(mm) | 320 | 330 | 330 | 340 | 345 | 345 | 360 | 380 | 400 | 430 |
W(mm) | 105 | 115 | 115 | 125 | 130 | 130 | 145 | 165 | 185 | 215 |
D(mm) | 50.5 | 50.5 | 50.5 | 50.5 | 64 | 77.5 | 91 | 106 | 119 | 145 |
d1(mm) | 19.05 | 25.4 | 34.8 | 34 | 45 | 57 | 70 | 85 | 108 | 133 |
d2(mm) | 16.05 | 22.4 | 28.8 | 31 | 42 | 53 | 66 | 81 | 104 | 128 |
L1(mm) | 21.5 | 21.5 | 21.5 | 21.5 | 21.5 | 21.5 | 21.5 | 21.5 | 21.5 | 21.5 |