Electromagnetic FlowmeterElectromagnetic FlowmeterElectromagnetic Flowmeter
Electromagnetic Flowmeter
Electromagnetic Flowmeter
Electromagnetic Flowmeter

Integrated Electromagnetic Flowmeter

HBLD intelligent electromagnetic flow meter is a high-performance, high-reliability flow meter. Used to measure the volume flow of conductive liquid and slurry in closed pipes. Widely used in steel, electricity, petroleum, chemical industry, coal, metallurgy, papermaking, water supply and drainage, food, pharmaceutical industry, etc.

Working principle

The measuring principle of electromagnetic flow meter is based on Faraday's law of electromagnetic induction. The sensor is mainly composed of a measuring tube with an insulating lining, a pair of electrodes installed by inserting the measuring tube wall, a pair of coils and an iron core to generate a working magnetic field. When a conductive fluid flows through the measuring tube of the sensor, a voltage signal proportional to the average flow rate of the fluid will be induced on the electrode. The signal is operationally amplified and processed to achieve various display functions.

Features

    • 01Measurements are not affected by fluid density, viscosity, temperature,pressure and conductivity.
    • 02No obstacles in the measuring tube, no pressure loss, low requirements for straight pipe section.
    • 03The LCD backlight type converter can be easily displayed and read in the sun or in a dark room.
    • 04In harsh environments, parameters can be set via infrared touch buttons without opening the cover of the converter (need to be customized).
    • 05Flow meter with bidirectional measurement system, built-in three totalizers: positive total, reverse total and total difference.
    • 06It has various forms of output: current 4-20mA, pulse, frequency, rs-485, HART.
    • 07The converter has self-diagnosis alarm output, no-load detection alarm output, flow upper and lower limit alarm, batch control (need to be customized) and other alarm output functions.
    • 08Not only for general processes, but also for the measurement of ore pulp, mud, coal slurry, paper pulp and paste liquid.
    • 09High-pressure electromagnetic flow sensor with PFA lining technology, resistant to high pressure and negative pressure, especially suitable for petroleum, chemical and other industries.
    • 10Explosion-proof instruments can be used in corresponding explosion-proof places.

Product Exhibition

————————Technical parameter———————

Applicable medium Various conductive liquids;
Caliber range DN3-DN3000 (DN3\DN4 is flange clamping type)
Lining type Polychloroprene rubber, PTFE, F46, PFA, silicon fluoride, polyurethane rubber;
Electrode type 316L, Ha B, Ha C, titanium, tantalum, platinum-iridium alloy, stainless steel tungsten carbide
Pressure range 0.6~42Mpa; (high pressure needs to be customized)
Temperature resistance -25~80℃;
Accuracy ±0.5%, can be customized ±0.3%, ±0.2%;
Protection level Sensor IP65\IP67\IP68 (optional), converter IP65
Integrated electromagnetic Flow meter Output type Frequency, pulse, 4-20mA, RS485, Modbus protocol; Hart protocol (optional), Profibus DP (optional):
Power supply 85~250V, 45~63Hz, 20VDC --- 36VDC
————————Technical parameter———————

Applicable medium Various conductive liquids;
Caliber range DN3-DN3000
Lining type Polychloroprene rubber, PTFE, F46, PFA, silicon fluoride, polyurethane rubber;
Electrode type 316L, Ha B, Ha C, titanium, tantalum, platinum-iridium alloy, stainless steel tungsten carbide
Pressure range 0.6~42Mpa; (high pressure needs to be customized)
Temperature resistance -25~80℃;
Accuracy ±0.5%, can be customized ±0.3%, ±0.2%;
Protection level Sensor IP65\IP67\IP68 (optional), converter IP65
Split electromagnetic Flow meter Output type frequency, pulse, 4-20mA, RS485, Modbus protocol; Hart protocol (optional), Profibus DP (optional)
Power supply 85~250V, 45~63Hz, 20VDC --- 36VDC
Flow rate table
mm,m3/h,m/s 0.5 1 2 3 4 5 15(maximum)
10 0.14 0.28 0.27 0.85 1.13 1.41 4.24
15 0.32 0.64 1.27 1.91 2.54 3.18 9.54
20 0.57 1.13 2.26 3.39 4.52 5.65 16.96
25 0.88 1.77 3.53 5.30 7.07 8.84 26.51
32 1.45 2.90 5.79 8.69 11.58 14.48 43.43
40 2.26 4.52 9.05 13.57 18.10 22.62 67.86
50 3.53 7.07 14.14 21.21 28.27 35.34 106.03
65 5.97 11.95 23.89 35.84 47.78 59.73 179.19
80 9.05 18.10 36.19 54.29 72.38 90.48 271.43
100 14.14 28.27 56.55 84.82 113.10 141.37 424.12
125 22.09 44.18 88.36 132.54 176.71 220.89 662.68
150 31.09 63.62 127.23 190.85 254.47 318.09 954.26
200 56.55 113.10 226.19 339.29 452.39 565.49 1696.46
250 88.36 176.71 363.43 530.14 706.86 883.57 2650.72
300 127.23 254.47 508.94 763.41 1017.88 1272.35 3817.04
350 173.18 346.36 692.72 1039.08 1385.44 1731.80 5195.41
400 226.19 452.39 904.78 1357.17 1809.56 2261.96 6785.84
450 286.28 572.56 1145.11 1717.67 2290.22 2862.78 8588.33
500 353.43 706.86 1413.72 2120.58 2827.43 3534.29 10602.88
600 508.94 1017.88 2035.75 3053.63 4071.50 5089.38 15268.14
700 692.72 1385.44 2770.88 4156.33 5541.77 6927.21 20781.64
800 904.78 1809.56 3619.11 5428.67 7238.23 9047.79 27143.36
900 1145.11 2290.22 4580.44 6870.66 9160.88 11451.11 34353.32
1000 1413.72 2827.43 5654.87 8482.30 11309.73 14137.13 42411.50
1200 2035.75 4071.50 8143.01 12214.51 16286.02 20357.52 61072.56
1400 2770.88 5541.77 11083.54 16625.31 22167.08 27708.85 83126.54
1600 3617.11 7238.23 14476.46 21714.69 28952.92 36191.15 108573.44
1800 4580.44 9160.88 18321.77 27482.65 36643.54 45804.42 137413.26
2000 5654.87 11309.73 22619.47 33929.20 45238.93 56548.67 169646.00
2200 6842.39 13684.78 27369.56 41054.33 54739.11 68423.89 205217.66
2400 8143.01 16286.02 32572.03 48858.05 65144.07 81430.08 244290.24
2600 9556.72 19113.43 38226.85 57340.71 76453.71 95567.13 206701.40
2800 11083.54 22167.90 44334.15 66501.23 88668.31 110835.39 332506.16
3000 12723.45 25446.90 50893.80 76340.70 101787.60 127234.50 381703.50

Electromagnetic flow meter sensor dimension drawing

Flange standard: JB/T 81-94(The company's standard product flange standard)

Unit: mm

Nominal diameter preset pressure L W H d1 d0-n Nominal diameter preset pressure L W H d1 d0-n
DN3 4.0 192 90 140 60 ⌀14*4 DN250 1.6 450 405 455 355 ⌀26*12
DN6 4.0 192 95 145 65 ⌀14*4 DN300 1.6 500 460 510 410 ⌀26*12
DN10 4.0 192 90 140 60 ⌀14*4 DN350 1.0 500 500 550 460 ⌀23*16
DN15 4.0 192 95 145 65 ⌀14*4 DN400 1.0 500 565 615 515 ⌀36*16
DN20 4.0 192 105 155 75 ⌀14*4 DN450 1.0 550 615 665 565 ⌀26*20
DN25 4.0 192 115 165 85 ⌀14*4 DN500 1.0 550 670 720 620 ⌀26*20
DN32 4.0 192 135 185 100 ⌀18*4 DN600 1.0 600 780 830 725 ⌀30*20
DN40 4.0 192 145 195 110 ⌀18*4 DN700 0.6 700 860 910 810 ⌀26*24
DN50 4.0 192 160 210 125 ⌀18*4 DN800 0.6 800 975 1025 920 ⌀30*24
DN65 1.6 250 180 230 145 ⌀18*4 DN900 0.6 900 1075 1125 1020 ⌀30*24
DN80 1.6 250 195 245 160 ⌀18*8 DN1000 0.6 1000 1175 1225 1120 ⌀30*28
DN100 1.6 250 215 265 180 ⌀18*8 DN1200 0.6 1200 1400 1450 1340 ⌀30*32
DN125 1.6 250 245 295 210 DN1400 0.6 1400 1620 1670 1560 ⌀30*36
DN150 1.6 300 280 330 240
DN200 1.6 350 335 385 295

More flange standard size reference table (please specify before ordering)